Any views expressed within media held on this service are those of the contributors, should not be taken as approved or endorsed by the University, and do not necessarily reflect the views of the University in respect of any particular issue.
Improving inter-observer agreement about brain microbleeds: development of the Brain Observer MicroBleed Scale (BOMBS)

Improving inter-observer agreement about brain microbleeds: development of the Brain Observer MicroBleed Scale (BOMBS)

If the diagnostic and prognostic significance of brain microbleeds (BMBs) are to be investigated and used for these purposes in clinical practice, observer variation in BMB assessment must be minimized.

METHODS:

Two doctors used a pilot rating scale to describe the number and distribution of BMBs (round, low-signal lesions, <10 mm diameter on gradient echo MRI) among 264 adults with stroke or TIA. They were blinded to clinical data and their counterpart’s ratings. Disagreements were adjudicated by a third observer, who informed the development of a new Brain Observer MicroBleed Scale (BOMBS), which was tested in a separate cohort of 156 adults with stroke.

RESULTS:

In the pilot study, agreement about the presence of >/=1 BMB in any location was moderate (kappa=0.44; 95% CI, 0.32-0.56), but agreement was worse in lobar locations (kappa=0.44; 95% CI, 0.30-0.58) than in deep (kappa=0.62; 95% CI, 0.48-0.76) or posterior fossa locations (kappa=0.66; 95% CI, 0.47-0.84). Using BOMBS, agreement about the presence of >/=1 BMB improved in any location (kappa=0.68; 95% CI, 0.49-0.86) and in lobar locations (kappa=0.78; 95% CI, 0.60-0.97).

CONCLUSIONS:

Interrater reliability concerning the presence of BMBs was moderate to good, and could be improved with the use of the BOMBS rating scale, which takes into account the main sources of interrater disagreement identified by our pilot scale.

Share

css.php

Report this page

To report inappropriate content on this page, please use the form below. Upon receiving your report, we will be in touch as per the Take Down Policy of the service.

Please note that personal data collected through this form is used and stored for the purposes of processing this report and communication with you.

If you are unable to report a concern about content via this form please contact the Service Owner.

Please enter an email address you wish to be contacted on. Please describe the unacceptable content in sufficient detail to allow us to locate it, and why you consider it to be unacceptable.
By submitting this report, you accept that it is accurate and that fraudulent or nuisance complaints may result in action by the University.

  Cancel